On Installation
- When installing the unit, leave space between any walls, etc. and the unit as illustrated.
Top view
A: More than 50 cm (19 11/16 inches)
B: More than 50 cm (19 11/16 inches) - Avoid using the unit in a location where the temperature or humidity is very high, or temperature is very low.
- Avoid installing the unit in a location subject to direct cool or warm air from an air-conditioner. Installing in such a location may cause malfunction of the unit due to moisture condensation or rise in temperature.
- Avoid installing the unit in a location near a heat or smoke sensor. Installing in such a location may cause malfunction of the sensor.
- Avoid installing the unit in a very dusty or extremely smoky environment. Otherwise, the air filter will become obstructed, and this may cause a malfunction of the unit or damage it.
- When using the unit in a location at an altitude of 1,000 m (approx. 3,280 feet) or higher, appropriately set [High Altitude Mode] in the [Installation] menu. Failing to do so could have adverse effects, such as reducing the reliability of certain components.