Specifications

Flash unit

Flash control Flash control using pre-flash (P-TTL/ADI)
Continuous flash performance 40 flashes (HVL-F60RM)/200 flashes (HVL-F60RM2)/60 flashes (HVL-F46RM) at 10 flashes per second (Normal flash, flash power level 1/32, camera shutter speed of less than 1/250, nickel-metal hydride batteries)
AF illuminator (HVL-F60RM)

Autoflash at low contrast and low brightness

Operating range (While a 50mm lens with the aperture set at F5.6 is attached.)

  • [AF LED LEVEL] of the flash unit is specified as [LOW]

    • Central area (Approx.): 0.5 m to 3 m (1 ft. 7 3/4 in. to 9 ft. 10 1/8 in.)

    • Peripheral areas (Approx.): 0.5 m to 2 m (1 ft. 7 3/4 in. to 6 ft. 6 3/4 in.)

  • [AF LED LEVEL] of the flash unit is specified as [HIGH]

    • Central area (Approx.): 0.5 m to 10 m (1 ft. 7 3/4 in. to 32 ft. 9 3/4 in.)

    • Peripheral areas (Approx.): 0.5 m to 6 m (1 ft. 7 3/4 in. to 19 ft. 8 1/4 in.)

LED light (HVL-F60RM)
  • Center luminance intensity: Approx. 1 200 lx at 0.5 m (1 ft. 7 3/4 in.) or approx. 300 lx at 1 m (3 ft. 3 3/8 in.)

  • Lighting distance: Approx. 2 m (6 ft. 6 3/4 in.) (when recording movies, set to ISO 3200 & F5.6)

  • Focal length supported: 35 mm (35mm-format angle of view)

  • Continuous lighting time: Approx. 1 hour (using AA alkaline batteries, at center luminance intensity)

  • Color temperature: Approx. 5 500 K

Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
Storage temperature

HVL-F60RM: –20 °C to +60 °C (–4 °F to +140 °F)

HVL-F60RM2/HVL-F46RM: –20 °C to +55 °C (–4 °F to +131 °F)

Dimension (w/h/d)(Approx.)

HVL-F60RM: 78.1 mm × 139.5 mm × 104.6 mm (3 1/8 in. × 5 1/2 in. × 4 1/8 in.)

HVL-F60RM2: 78.1 mm × 143.1 mm × 104.6 mm (3 1/8 in. × 5 3/4 in. × 4 1/8 in.)

HVL-F46RM: 69.4 mm × 114.7 mm × 88.9 mm (2 3/4 in. × 4 5/8 in. × 3 1/2 in.)

Mass (Approx.)

HVL-F60RM: 449 g (15.9 oz) (excluding the batteries)

HVL-F60RM2: 439 g (15.5 oz) (excluding the batteries)

HVL-F46RM: 308 g (10.9 oz) (excluding the batteries)

Power requirements DC 6 V
Recommended batteries
  • Four LR6 (AA-size) alkaline batteries

  • Four AA-size rechargeable nickel-metal hydride batteries

Flash frequency/count

The flash count indicates the approximate number of flashes available before new batteries wear out.

  • HVL-F60RM

Flash frequency/count With alkaline batteries With nickel-metal hydride batteries
Flash frequency (sec)(*1) Approx. 0.1 - 2.5 Approx. 0.1 - 1.7
Flash count (times)(*2) Approx. 150 or more Approx. 220 or more

  • HVL-F60RM2

Flash frequency/count With alkaline batteries With nickel-metal hydride batteries
Flash frequency (sec)(*1) Approx. 0.1 - 2.5 Approx. 0.1 - 1.7
Flash count (times)(*2) Approx. 160 or more Approx. 240 or more

  • HVL-F46RM

Flash frequency/count With alkaline batteries With nickel-metal hydride batteries
Flash frequency (sec)(*1) Approx. 0.1 - 2.5 Approx. 0.1 - 2.0
Flash count (times)(*2) Approx. 240 or more Approx. 320 or more

*1 Minimum duration of time before the TEST button lights after the previous flash (Acquired under our measurement conditions.) (HVL-F60RM2/HVL-F46RM (flash unit software version 2.00 or later): When [CHG PRIORITY] is set to [NORMAL])

*2 Number of flashes at the highest flash power level available in every 30 seconds (Acquired under our measurement conditions.)

Functions in this manual depend on testing conditions at our firm.