[Technical] Menu
The following tables describe the function and settings of each menu item.
[Technical] – [Color Bars]
Sets color bar settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Setting] | [On] / [Off] | [Off] | Turns color bars on/off. |
| [Type] | ARIB / 100% / 75% / SMPTE | ARIB | Selects the color bar type. |
[Technical] – [ND Dial]
Sets settings related to ND VARIABLE dial operations.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [CLEAR with Dial] | [On] / [Off] | [On] | Sets whether to enable ND filter status switching ([Clear] ⇔ [On]) by ND VARIABLE dial operation. |
[Technical] – [Tally]
Sets recording/tally lamp settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Front Tally Lamp] | [On] / [Off] | [On] | Turns the recording/tally lamp (front) on/off. |
| [Rear Tally Lamp] | [On] / [Off] | [On] | Turns the recording/tally lamp (rear) on/off. |
[Technical] – [Touch Operation]
Sets settings related to touch operation.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Setting] | [On] / [Off] | [On] | Turns touch operation on/off. |
[Technical] – [Rec Review]
Sets recording review settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Setting] | [3s] / [10s] / [Clip] | [3s] | Selects the time for playback of clips just recorded for recording review. |
[Technical] – [Handle Zoom]
Sets handle zoom settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Setting] | [Off] / [Low] / [High] / [Variable] | [Variable] | Sets the speed of the handle zoom. |
| [High] | 1 to 8 | 8 | Sets the zoom speed when the handle zoom lever is pressed when [Setting] is set to [High]. |
| [Low] | 1 to 8 | 3 |
Sets the zoom speed when the handle zoom lever is pressed when [Setting] is set to [Low]. Note
|
[Technical] – [GPS]
Sets settings related to location data recording.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Location by Mobile App] | [On] / [Off] | [Off] | Turns acquisition of location data from the “Creators' App for Enterprise” smartphone application on/off. |
[Technical] – [Menu Settings]
Sets settings related to the menu.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [User Menu Only] | [On] / [Off] | [Off] | Sets whether to display the [User] menu only or display the menu list when the unit displays the menu. [On]: Displays the [User] menu only. [Off]: Displays the menu list. |
| [Menu Page On/Off] | [
|
– | Turns the status screen display on/off. |
| [User Menu with Lock] | [On] / [Off] | [Off] |
Sets whether to lock the menu display, showing the [User] menu only. Note
|
[Technical] – [Fan Control]
Sets fan control mode settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Setting] | [Auto] / [Minimum] / [Off in Rec] | [Auto] |
Sets the control mode of the fan. Note
|
[Technical] – [Lens]
Sets settings related to lenses.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Distortion Comp.] | [Auto] / [Off] | [Auto] | Sets automatic distortion compensation. |
| [Auto FB Adjust] | [Execute] / [Cancel] | – | Initializes the flange focal distance auto adjustment/adjustment value for the lens. [Execute]: Execute function. |
| [Distance Display] | [Meter] / [Feet] | [Meter] | Sets the display units for lens information and focus position. |
| [Zoom Position Display] | [Number] / [Bar] | [Number] | Sets the display format for the zoom position. |
[Technical] – [APR]
Executes APR.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [APR] | [Execute] / [Cancel] | – | Executes APR (Auto Pixel Restoration). [Execute]: Execute function. |
[Technical] – [Camera Battery Alarm]
Sets battery low-voltage alarm settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [Low Battery] | 5% / 10% / 15% / --- / 45% / 50% | 10% | Sets the remaining battery level to display a battery low-voltage alarm (5% increments). |
| [Battery Empty] | 3% to 7% | 3% | Sets the remaining battery level to display a battery empty alarm. |
[Technical] – [Camera DC IN Alarm]
Sets input voltage alarm settings.
| Menu item | Sub-item setting | Factory default value | Description |
|---|---|---|---|
| [DC Low Voltage1] | 16.0V to 21.0V | 18.5V | Sets the voltage to display a DC IN low input voltage alarm. |
| [DC Low Voltage2] | 16.0V to 20.0V | 18.0V | Sets the voltage to display a DC IN insufficient input voltage alarm. |
TP1002071035