[Auto Exposure]

Sets automatic exposure adjustment settings.

Item Sub-item setting Factory default Description
[Level] +3.0 / +2.75 / +2.5 / +2.25 / +2.0 / +1.75 / +1.5 / +1.25 / +1.0 / +0.75 / +0.5 / +0.25 / ±0 / –0.25 / –0.5 / –0.75 / –1.0 / –1.25 / –1.5 / –1.75 / –2.0 / –2.25 / –2.5 / –2.75 / –3.0 ±0 Sets the brightness level for the automatically detected exposure.
[Mode] [Backlight] / [Standard] / [Spotlight] [Standard] Sets the operating mode of auto exposure adjustment.
[Backlight]: Backlight mode (mode for reduced darkening of shadows when the subject is backlit)
[Standard]: Standard mode
[Spotlight]: Spotlight mode (mode for reduced clipped whites when subject is lit by spotlighting)
[Speed] −99 to +99 ±0 Sets the adjustment speed of auto exposure adjustment.
[AGC] [On] / [Off] [Off] Turns auto gain control on/off.
[AGC Limit]
  • For details about settings, see “AGC Limit Settings and Default Values.”
Sets the maximum gain of the auto gain control.
[AGC Point] F2.8 / F4 / F5.6 F2.8 Sets the F-number of the iris where auto gain control operation starts when [AGC] is set to [On].
[Auto Shutter] [On] / [Off] [Off] Turns auto shutter on/off.
[A.SHT Limit] 1/100 / 1/150 / 1/200 / 1/250 / 1/2000 1/2000 Sets the fastest shutter speed of the auto shutter.
[A.SHT Point] F5.6 / F8 / F11 F8 Sets the F-number of the iris where auto shutter operation starts when [Auto Shutter] is set to [On].
[Clip High light] [On] / [Off] [Off] Turns the function that ignores brightest areas to provide a flatter response at high luminance on/off.
[Detect Window] 1 / 2 / 3 / 4 / 5 / 6 / Custom 1 Sets the light metering range for automatically adjusting the exposure according to the brightness of the subject. (Not available when adjusting exposure manually)
[Detect Window Indication] [On] / [Off] [Off] Turns the light metering range indication on/off.
[Custom Width] 40 to 999 500 Sets the width of the light metering range.
[Custom Height] 70 to 999 500 Sets the height of the light metering range.
[Custom H Position] –479 to +479 ±0 Sets the horizontal position of the light metering range.
[Custom V Position] –464 to +464 ±0 Sets the vertical position of the light metering range.
 