[Auto Exposure]
Sets automatic exposure adjustment settings.
Item | Sub-item setting | Factory default | Description |
---|---|---|---|
[Level] | +3.0 / +2.75 / +2.5 / +2.25 / +2.0 / +1.75 / +1.5 / +1.25 / +1.0 / +0.75 / +0.5 / +0.25 / ±0 / –0.25 / –0.5 / –0.75 / –1.0 / –1.25 / –1.5 / –1.75 / –2.0 / –2.25 / –2.5 / –2.75 / –3.0 | ±0 | Sets the brightness level for the automatically detected exposure. |
[Mode] | [Backlight] / [Standard] / [Spotlight] | [Standard] | Sets the operating mode of auto exposure adjustment. [Backlight]: Backlight mode (mode for reduced darkening of shadows when the subject is backlit) [Standard]: Standard mode [Spotlight]: Spotlight mode (mode for reduced clipped whites when subject is lit by spotlighting) |
[Speed] | −99 to +99 | ±0 | Sets the adjustment speed of auto exposure adjustment. |
[AGC] | [On] / [Off] | [Off] | Turns auto gain control on/off. |
[AGC Limit] |
|
– | Sets the maximum gain of the auto gain control. |
[AGC Point] | F2.8 / F4 / F5.6 | F2.8 | Sets the F-number of the iris where auto gain control operation starts when [AGC] is set to [On]. |
[Auto Shutter] | [On] / [Off] | [Off] | Turns auto shutter on/off. |
[A.SHT Limit] | 1/100 / 1/150 / 1/200 / 1/250 / 1/2000 | 1/2000 | Sets the fastest shutter speed of the auto shutter. |
[A.SHT Point] | F5.6 / F8 / F11 | F8 | Sets the F-number of the iris where auto shutter operation starts when [Auto Shutter] is set to [On]. |
[Clip High light] | [On] / [Off] | [Off] | Turns the function that ignores brightest areas to provide a flatter response at high luminance on/off. |
[Detect Window] | 1 / 2 / 3 / 4 / 5 / 6 / Custom | 1 | Sets the light metering range for automatically adjusting the exposure according to the brightness of the subject. (Not available when adjusting exposure manually) |
[Detect Window Indication] | [On] / [Off] | [Off] | Turns the light metering range indication on/off. |
[Custom Width] | 40 to 999 | 500 | Sets the width of the light metering range. |
[Custom Height] | 70 to 999 | 500 | Sets the height of the light metering range. |
[Custom H Position] | –479 to +479 | ±0 | Sets the horizontal position of the light metering range. |
[Custom V Position] | –464 to +464 | ±0 | Sets the vertical position of the light metering range. |
TP1001804591