Synchronizing the Phase of the Video Signal (Genlock)
You can supply a reference signal to the GENLOCK connector to enable genlock.
The input reference signals that can be used vary depending on the system frequency of the selected recording format.
| System frequency of recording format | Supported input reference signals |
|---|---|
| 119.88 | 1920×1080 59.94i 720×486 59.94i |
| 100 | 1920×1080 50i 720×576 50i |
| 59.94 | 1920×1080 59.94i 720×486 59.94i |
| 50 | 1920×1080 50i 720×576 50i |
| 29.97 | 1920×1080 59.94i 720×486 59.94i |
| 25 | 1920×1080 50i 720×576 50i |
| 23.98 | 1920×1080 23.98PsF 1920×1080 23.98P |
You can check the external sync status using [Technical] – [Genlock] – [Reference] in the camera menu.
Note
- If the reference signal is unstable, genlock cannot be achieved.
- The subcarrier is not synchronized.
TP1001804708