Synchronizing the Phase of the Video Signal (Genlock)
You can supply a reference signal to the GENLOCK connector to enable genlock.
The input reference signals that can be used vary depending on the system frequency of the selected recording format.
| System frequency of recording format | Supported input reference signals |
|---|---|
| 59.94P | 1920×1080 59.94i 720×486 59.94i |
| 50P | 1920×1080 50i 720×576 50i |
| 29.97P | 1920×1080 59.94i 720×486 59.94i |
| 25P | 1920×1080 50i 720×576 50i |
| 24P | 1920×1080 24PsF 1920×1080 24P |
| 23.98P | 1920×1080 23.98PsF 1920×1080 23.98P |
| 59.94i | 1920×1080 59.94i 720×486 59.94i |
| 50i | 1920×1080 50i 720×576 50i |
You can check the external sync status using [Technical] > [Genlock] > [Reference] in the camera menu.
Note
- If the reference signal is unstable, genlock cannot be achieved.
- The subcarrier is not synchronized.
- When using external synchronization in a noisy environment, tri-level sync is recommended due to its strong noise immunity.