Auto Exposure

Sets automatic exposure adjustment settings.

Item Sub-item setting Factory default Description
Level +3.0 / +2.75 / +2.5 / +2.25 / +2.0 / +1.75 / +1.5 / +1.25 / +1.0 / +0.75 / +0.5 / +0.25 / ±0 / −0.25 / −0.5 / −0.75 / −1.0 / −1.25 / −1.5 / −1.75 / −2.0 / −2.25 / −2.5 / −2.75 / −3.0 ±0 Sets the brightness level for the automatically detected exposure.
Mode Backlight / Standard / Spotlight Standard Sets the operating mode of auto exposure adjustment.
Backlight: Backlight mode (mode for reduced darkening of a subject when the subject is backlit)
Standard: Standard mode
Spotlight: Spotlight mode (mode for reduced clipped whites when subject is lit by spotlighting)
Speed −99 to +99 ±0 Sets the adjustment speed of auto exposure adjustment.
AGC On / Off Off Turns the AGC (auto gain control) function on/off.
AGC Limit
  • For details about settings, see “AGC Limit Settings and Default Values.”
Sets the maximum gain of the AGC function.
AGC Point F2.8 / F4 / F5.6 F2.8 Sets the F-stop value of the iris where AGC operation starts when the AGC function is On.
Auto Shutter On / Off Off Turns the auto shutter control function on/off.
A.SHT Limit 1/100 / 1/150 / 1/200 / 1/250 / 1/2000 1/2000 Sets the fastest shutter speed of the auto shutter function.
A.SHT Point F5.6 / F8 / F11 / F16 F11 Sets the F-stop value of the iris where auto shutter operation starts.
Clip High light On / Off Off Turns the function that ignores brightest areas to provide a flatter response at high luminance on/off.
Detect Window 1 / 2 / 3 / 4 / 5 / 6 / Custom 1 Sets the light metering range for automatically adjusting the exposure according to the brightness of the subject. (Not available when adjusting exposure manually)
Detect Window Indication On / Off Off Turns the light metering range indication on/off.
Custom Width 40 to 999 500 Sets the width of the light metering range.
Custom Height 70 to 999 500 Sets the height of the light metering range.
Custom H Position −479 to +479 ±0 Sets the horizontal position of the light metering range.
Custom V Position −464 to +464 ±0 Sets the vertical position of the light metering range.